FM Transmitter Measurement Report
Created: 2024-12-06 07-23-00
Measuring equipment: P75/P175/P275 |
http://pira.cz |
Station Details
Frequency |
Signal
Reception |
Station
Name |
90.30 MHz |
5/5, 63 dBuV |
VIBRA fm |
Pilot |
RDS |
Phase
Difference |
6.7 kHz |
3.3 kHz |
-65 deg |
|
Frequency Deviation
Limit |
Measuring
Tolerance |
75,0 kHz |
0,0 kHz |
MIN
Hold |
Max. Samples at |
Total
Samples |
% above 75,0
kHz |
8 kHz |
72 kHz |
17114 |
3,2313 |
|
Modulation Power
Limit |
Measuring
Tolerance |
10,0 dBr |
3,0 dBr |
MIN |
AVE |
MAX |
% above
13,0 dBr |
6,1 dBr |
7,23 dBr |
8,2 dBr |
0,0 |
|
Radio Data System
PS |
PI |
PTY |
TP |
TA |
MS |
DI |
CT |
"VIBRA fm" |
F560 |
9 (Varied) |
1 |
0 |
1 |
1 |
--:-- |
RT |
"VIBRATION - Vibrez avec nous " |
AF |
EON |
90.3, 93.1, 93.7, 97.7, 100.8, 101.7, 102.0 MHz |
- |
|
|